{"id":1441,"date":"2018-12-27T14:39:05","date_gmt":"2018-12-27T13:39:05","guid":{"rendered":"https:\/\/navlab.fr\/projets\/?p=1441"},"modified":"2018-12-27T14:54:01","modified_gmt":"2018-12-27T13:54:01","slug":"ajustement-du-laser-dun-cipherlab-8360","status":"publish","type":"post","link":"https:\/\/navlab.fr\/projets\/2018\/12\/27\/ajustement-du-laser-dun-cipherlab-8360\/","title":{"rendered":"Ajustement du laser d&rsquo;un CipherLab 8360"},"content":{"rendered":"<p>L&rsquo;autre jour B\u00e9ryl m&rsquo;a apport\u00e9 un PDA qu&rsquo;elle utilise pour g\u00e9rer les stocks de son magasin : lors d&rsquo;une grosse action commerciale, une de ses vendeuses l&rsquo;a fait tomber, et le laser qui sert \u00e0 scanner les codes barres s&rsquo;est d\u00e9cal\u00e9. R\u00e9sultat : impossible de scanner, le PDA est inutilisable !<\/p>\n<p>Le module du laser a \u00e9t\u00e9 \u00ab\u00a0bouscul\u00e9\u00a0\u00bb lors du choc, et celui-ci se retrouve d\u00e9sormais dans une mauvaise position. Voyons comment le replacer, c&rsquo;est tr\u00e8s simple.<\/p>\n<h4>Premi\u00e8re \u00e9tape : ouvrir le PDA<\/h4>\n<p>Ouvrir le PDA est tr\u00e8s simple : il suffit d&rsquo;\u00f4ter la batterie en faisant pivoter les petites charni\u00e8res de maintien et de retirer les 8 vis apparentes. Il vous faudra pour cela un petit tournevis cruciforme suffisamment fin. Personnellement, j&rsquo;utilise le <a href=\"http:\/\/rover.ebay.com\/rover\/1\/709-53476-19255-0\/1?ff3=4&amp;pub=5575320638&amp;toolid=10001&amp;campid=5338163104&amp;customid=brunomessin&amp;mpre=https%3A%2F%2Fwww.ebay.fr%2Fitm%2FIfixit-Manta-Driver-Kit-112-Bit%2F173325441059%3Fhash%3Ditem285b005823%3Ag%3AYOoAAOSwx95a%7E8sz\">kit Manta Driver de iFixIt<\/a> : il y a vraiment tout ce qu&rsquo;il faut !<\/p>\n<figure id=\"attachment_1451\" aria-describedby=\"caption-attachment-1451\" style=\"width: 597px\" class=\"wp-caption alignnone\"><a href=\"https:\/\/navlab.fr\/projets\/wp-content\/uploads\/sites\/3\/2018\/12\/R\u00e9paration-PDA-CipherLab-8360-02.jpg\"><img decoding=\"async\" loading=\"lazy\" class=\"size-full wp-image-1451\" src=\"https:\/\/navlab.fr\/projets\/wp-content\/uploads\/sites\/3\/2018\/12\/R\u00e9paration-PDA-CipherLab-8360-02.jpg\" alt=\"\" width=\"597\" height=\"800\" srcset=\"https:\/\/navlab.fr\/projets\/wp-content\/uploads\/sites\/3\/2018\/12\/R\u00e9paration-PDA-CipherLab-8360-02.jpg 597w, https:\/\/navlab.fr\/projets\/wp-content\/uploads\/sites\/3\/2018\/12\/R\u00e9paration-PDA-CipherLab-8360-02-224x300.jpg 224w, https:\/\/navlab.fr\/projets\/wp-content\/uploads\/sites\/3\/2018\/12\/R\u00e9paration-PDA-CipherLab-8360-02-100x134.jpg 100w, https:\/\/navlab.fr\/projets\/wp-content\/uploads\/sites\/3\/2018\/12\/R\u00e9paration-PDA-CipherLab-8360-02-150x201.jpg 150w, https:\/\/navlab.fr\/projets\/wp-content\/uploads\/sites\/3\/2018\/12\/R\u00e9paration-PDA-CipherLab-8360-02-200x268.jpg 200w, https:\/\/navlab.fr\/projets\/wp-content\/uploads\/sites\/3\/2018\/12\/R\u00e9paration-PDA-CipherLab-8360-02-300x402.jpg 300w, https:\/\/navlab.fr\/projets\/wp-content\/uploads\/sites\/3\/2018\/12\/R\u00e9paration-PDA-CipherLab-8360-02-450x603.jpg 450w\" sizes=\"(max-width: 597px) 100vw, 597px\" \/><\/a><figcaption id=\"caption-attachment-1451\" class=\"wp-caption-text\">Une fois d\u00e9mont\u00e9, d\u00e9branchez le petit connecteur blanc de la carte m\u00e8re.<\/figcaption><\/figure>\n<h4>Deuxi\u00e8me \u00e9tape : acc\u00e9der au module laser<\/h4>\n<p>Le module du laser du scanner est accessible en d\u00e9montant la carte \u00e9lectronique sup\u00e9rieure. Pour cela, d\u00e9vissez les deux vis qui maintiennent la carte en place. Attention, la carte est maintenue en place \u00e0 l&rsquo;aide d&rsquo;une colle repositionnable. Tirez l\u00e9g\u00e8rement pour la d\u00e9coller.<\/p>\n<figure id=\"attachment_1452\" aria-describedby=\"caption-attachment-1452\" style=\"width: 597px\" class=\"wp-caption alignnone\"><a href=\"https:\/\/navlab.fr\/projets\/wp-content\/uploads\/sites\/3\/2018\/12\/R\u00e9paration-PDA-CipherLab-8360-03.jpg\"><img decoding=\"async\" loading=\"lazy\" class=\"wp-image-1452 size-full\" src=\"https:\/\/navlab.fr\/projets\/wp-content\/uploads\/sites\/3\/2018\/12\/R\u00e9paration-PDA-CipherLab-8360-03.jpg\" alt=\"\" width=\"597\" height=\"800\" srcset=\"https:\/\/navlab.fr\/projets\/wp-content\/uploads\/sites\/3\/2018\/12\/R\u00e9paration-PDA-CipherLab-8360-03.jpg 597w, https:\/\/navlab.fr\/projets\/wp-content\/uploads\/sites\/3\/2018\/12\/R\u00e9paration-PDA-CipherLab-8360-03-224x300.jpg 224w, https:\/\/navlab.fr\/projets\/wp-content\/uploads\/sites\/3\/2018\/12\/R\u00e9paration-PDA-CipherLab-8360-03-100x134.jpg 100w, https:\/\/navlab.fr\/projets\/wp-content\/uploads\/sites\/3\/2018\/12\/R\u00e9paration-PDA-CipherLab-8360-03-150x201.jpg 150w, https:\/\/navlab.fr\/projets\/wp-content\/uploads\/sites\/3\/2018\/12\/R\u00e9paration-PDA-CipherLab-8360-03-200x268.jpg 200w, https:\/\/navlab.fr\/projets\/wp-content\/uploads\/sites\/3\/2018\/12\/R\u00e9paration-PDA-CipherLab-8360-03-300x402.jpg 300w, https:\/\/navlab.fr\/projets\/wp-content\/uploads\/sites\/3\/2018\/12\/R\u00e9paration-PDA-CipherLab-8360-03-450x603.jpg 450w\" sizes=\"(max-width: 597px) 100vw, 597px\" \/><\/a><figcaption id=\"caption-attachment-1452\" class=\"wp-caption-text\">La vis de maintien est sortie de son logement lors du choc.<\/figcaption><\/figure>\n<h4>Troisi\u00e8me \u00e9tape : repositionner le laser<\/h4>\n<p>Dans notre cas, nous voyons que l&rsquo;une des vis qui maintien le bloc laser est sortie de son logement : le choc a fendu la platine en plastique et le bloc laser n&rsquo;est plus align\u00e9 correctement. Il nous suffit de d\u00e9visser la vis fautive et de repositionner le bloc \u00e0 son emplacement. Pour plus de s\u00fbret\u00e9, nous ajouterons un point de colle au niveau de la platine fendue, avant de revisser le bloc en place.<\/p>\n<figure id=\"attachment_1453\" aria-describedby=\"caption-attachment-1453\" style=\"width: 800px\" class=\"wp-caption alignnone\"><a href=\"https:\/\/navlab.fr\/projets\/wp-content\/uploads\/sites\/3\/2018\/12\/R\u00e9paration-PDA-CipherLab-8360-04.jpg\"><img decoding=\"async\" loading=\"lazy\" class=\"size-full wp-image-1453\" src=\"https:\/\/navlab.fr\/projets\/wp-content\/uploads\/sites\/3\/2018\/12\/R\u00e9paration-PDA-CipherLab-8360-04.jpg\" alt=\"\" width=\"800\" height=\"597\" srcset=\"https:\/\/navlab.fr\/projets\/wp-content\/uploads\/sites\/3\/2018\/12\/R\u00e9paration-PDA-CipherLab-8360-04.jpg 800w, https:\/\/navlab.fr\/projets\/wp-content\/uploads\/sites\/3\/2018\/12\/R\u00e9paration-PDA-CipherLab-8360-04-300x224.jpg 300w, https:\/\/navlab.fr\/projets\/wp-content\/uploads\/sites\/3\/2018\/12\/R\u00e9paration-PDA-CipherLab-8360-04-768x573.jpg 768w, https:\/\/navlab.fr\/projets\/wp-content\/uploads\/sites\/3\/2018\/12\/R\u00e9paration-PDA-CipherLab-8360-04-100x75.jpg 100w, https:\/\/navlab.fr\/projets\/wp-content\/uploads\/sites\/3\/2018\/12\/R\u00e9paration-PDA-CipherLab-8360-04-150x112.jpg 150w, https:\/\/navlab.fr\/projets\/wp-content\/uploads\/sites\/3\/2018\/12\/R\u00e9paration-PDA-CipherLab-8360-04-200x149.jpg 200w, https:\/\/navlab.fr\/projets\/wp-content\/uploads\/sites\/3\/2018\/12\/R\u00e9paration-PDA-CipherLab-8360-04-450x336.jpg 450w, https:\/\/navlab.fr\/projets\/wp-content\/uploads\/sites\/3\/2018\/12\/R\u00e9paration-PDA-CipherLab-8360-04-600x448.jpg 600w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/a><figcaption id=\"caption-attachment-1453\" class=\"wp-caption-text\">Le bloc laser est de nouveau en place.<\/figcaption><\/figure>\n<h4>Quatri\u00e8me \u00e9tape : refermer et tester<\/h4>\n<p>Il ne nous reste plus qu&rsquo;\u00e0 refermer le boitier et \u00e0 tester. Tout d&rsquo;abord, replacez la carte sup\u00e9rieure puis reconnectez le petit connecteur blanc sur la carte m\u00e8re (aidez-vous de la pince fournie avec le kit si comme pour moi les c\u00e2bles sont tr\u00e8s courts et vos doigts trop gros !). Il ne vous reste plus qu&rsquo;\u00e0 replacer les 8 vis du boitier et \u00e0 remettre la batterie. V\u00e9rifiez votre laser : il est de nouveau centr\u00e9, et votre PDA fonctionne \u00e0 nouveau !!<\/p>\n<figure id=\"attachment_1450\" aria-describedby=\"caption-attachment-1450\" style=\"width: 597px\" class=\"wp-caption alignnone\"><a href=\"https:\/\/navlab.fr\/projets\/wp-content\/uploads\/sites\/3\/2018\/12\/R\u00e9paration-PDA-CipherLab-8360-01.jpg\"><img decoding=\"async\" loading=\"lazy\" class=\"size-full wp-image-1450\" src=\"https:\/\/navlab.fr\/projets\/wp-content\/uploads\/sites\/3\/2018\/12\/R\u00e9paration-PDA-CipherLab-8360-01.jpg\" alt=\"\" width=\"597\" height=\"800\" srcset=\"https:\/\/navlab.fr\/projets\/wp-content\/uploads\/sites\/3\/2018\/12\/R\u00e9paration-PDA-CipherLab-8360-01.jpg 597w, https:\/\/navlab.fr\/projets\/wp-content\/uploads\/sites\/3\/2018\/12\/R\u00e9paration-PDA-CipherLab-8360-01-224x300.jpg 224w, https:\/\/navlab.fr\/projets\/wp-content\/uploads\/sites\/3\/2018\/12\/R\u00e9paration-PDA-CipherLab-8360-01-100x134.jpg 100w, https:\/\/navlab.fr\/projets\/wp-content\/uploads\/sites\/3\/2018\/12\/R\u00e9paration-PDA-CipherLab-8360-01-150x201.jpg 150w, https:\/\/navlab.fr\/projets\/wp-content\/uploads\/sites\/3\/2018\/12\/R\u00e9paration-PDA-CipherLab-8360-01-200x268.jpg 200w, https:\/\/navlab.fr\/projets\/wp-content\/uploads\/sites\/3\/2018\/12\/R\u00e9paration-PDA-CipherLab-8360-01-300x402.jpg 300w, https:\/\/navlab.fr\/projets\/wp-content\/uploads\/sites\/3\/2018\/12\/R\u00e9paration-PDA-CipherLab-8360-01-450x603.jpg 450w\" sizes=\"(max-width: 597px) 100vw, 597px\" \/><\/a><figcaption id=\"caption-attachment-1450\" class=\"wp-caption-text\">Une belle \u00e9conomie de r\u00e9alis\u00e9e, et un appareil \u00e9lectronique de moins \u00e0 la poubelle !<\/figcaption><\/figure>\n","protected":false},"excerpt":{"rendered":"<p>L&rsquo;autre jour B\u00e9ryl m&rsquo;a apport\u00e9 un PDA qu&rsquo;elle utilise pour g\u00e9rer les stocks de son magasin : lors d&rsquo;une grosse action commerciale, une de ses vendeuses l&rsquo;a fait tomber, et le laser qui sert \u00e0 scanner les codes barres s&rsquo;est d\u00e9cal\u00e9. R\u00e9sultat : impossible de scanner, le PDA est inutilisable ! Le module du laser &hellip; <\/p>\n","protected":false},"author":2,"featured_media":1454,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":[],"categories":[38],"tags":[46,36],"_links":{"self":[{"href":"https:\/\/navlab.fr\/projets\/wp-json\/wp\/v2\/posts\/1441"}],"collection":[{"href":"https:\/\/navlab.fr\/projets\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/navlab.fr\/projets\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/navlab.fr\/projets\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/navlab.fr\/projets\/wp-json\/wp\/v2\/comments?post=1441"}],"version-history":[{"count":2,"href":"https:\/\/navlab.fr\/projets\/wp-json\/wp\/v2\/posts\/1441\/revisions"}],"predecessor-version":[{"id":1456,"href":"https:\/\/navlab.fr\/projets\/wp-json\/wp\/v2\/posts\/1441\/revisions\/1456"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/navlab.fr\/projets\/wp-json\/wp\/v2\/media\/1454"}],"wp:attachment":[{"href":"https:\/\/navlab.fr\/projets\/wp-json\/wp\/v2\/media?parent=1441"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/navlab.fr\/projets\/wp-json\/wp\/v2\/categories?post=1441"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/navlab.fr\/projets\/wp-json\/wp\/v2\/tags?post=1441"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}